CID-136-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 136 FMI 4 - Stick Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-137-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 3 - Bucket Position Sensor: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-137-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 4 - Bucket Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-137-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 5 - Bucket Position Sensor: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-137-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 137 FMI 6 - Bucket Position Sensor: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-138-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 138 FMI 3 - Swing Position Sensor: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-138-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 138 FMI 5 - Swing Position Sensor: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-138-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 138 FMI 6 - Swing Position Sensor: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-138-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 138 FMI 8 - Swing Position Sensor: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-139-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 139 FMI 6 - Left Track Position Sensor: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-14-FMI-13 |
CAT Electronic Control Module
|
Caterpillar CID 14 FMI 13 - Fuel Rail Pressure: Out of Calibration |
heavy-equipment |
Critical |
View → |
CID-14-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 14 FMI 6 - Fuel Rail Pressure: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Critical |
View → |
CID-140-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 140 FMI 1 - Right Track Position Sensor: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-140-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 140 FMI 2 - Right Track Position Sensor: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-140-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 140 FMI 3 - Right Track Position Sensor: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-140-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 140 FMI 4 - Right Track Position Sensor: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-141-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 141 FMI 1 - Boom Angle: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-141-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 141 FMI 2 - Boom Angle: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-141-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 141 FMI 3 - Boom Angle: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-141-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 141 FMI 5 - Boom Angle: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-142-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 142 FMI 2 - Stick Angle: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-142-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 142 FMI 4 - Stick Angle: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-142-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 142 FMI 6 - Stick Angle: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-143-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 143 FMI 4 - Bucket Angle: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-143-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 143 FMI 5 - Bucket Angle: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-143-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 143 FMI 6 - Bucket Angle: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-144-FMI-13 |
CAT Electronic Control Module
|
Caterpillar CID 144 FMI 13 - Swing Angle: Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-144-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 144 FMI 5 - Swing Angle: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-144-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 144 FMI 8 - Swing Angle: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-145-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 145 FMI 0 - Machine Pitch Angle: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-145-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 145 FMI 2 - Machine Pitch Angle: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-145-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 145 FMI 3 - Machine Pitch Angle: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-145-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 145 FMI 4 - Machine Pitch Angle: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-146-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 146 FMI 2 - Machine Roll Angle: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-147-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 147 FMI 2 - GPS Position Latitude: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-147-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 147 FMI 3 - GPS Position Latitude: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-147-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 147 FMI 4 - GPS Position Latitude: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-147-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 147 FMI 5 - GPS Position Latitude: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-148-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 148 FMI 3 - GPS Position Longitude: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-148-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 148 FMI 5 - GPS Position Longitude: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-148-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 148 FMI 6 - GPS Position Longitude: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-148-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 148 FMI 8 - GPS Position Longitude: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-149-FMI-13 |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 13 - GPS Altitude: Out of Calibration |
heavy-equipment |
Minor |
View → |
CID-149-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 4 - GPS Altitude: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-149-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 5 - GPS Altitude: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-149-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 6 - GPS Altitude: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-149-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 149 FMI 8 - GPS Altitude: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-15-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 0 - Fuel Injector #1: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-15-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 1 - Fuel Injector #1: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-15-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 3 - Fuel Injector #1: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-15-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 15 FMI 4 - Fuel Injector #1: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-150-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 0 - GPS Speed: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-150-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 1 - GPS Speed: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-150-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 3 - GPS Speed: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-150-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 150 FMI 4 - GPS Speed: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-151-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 151 FMI 2 - GPS Heading: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-151-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 151 FMI 3 - GPS Heading: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-152-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 152 FMI 2 - GPS Satellites: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-152-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 152 FMI 4 - GPS Satellites: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-152-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 152 FMI 5 - GPS Satellites: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-152-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 152 FMI 6 - GPS Satellites: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-153-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 153 FMI 3 - Radio Signal Strength: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-153-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 153 FMI 4 - Radio Signal Strength: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-153-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 153 FMI 5 - Radio Signal Strength: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-153-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 153 FMI 6 - Radio Signal Strength: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-153-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 153 FMI 8 - Radio Signal Strength: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-154-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 154 FMI 4 - Remote Shutdown Command: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Critical |
View → |
CID-154-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 154 FMI 8 - Remote Shutdown Command: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Critical |
View → |
CID-155-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 155 FMI 0 - Theft Deterrent System: Data Valid But Above Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-155-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 155 FMI 1 - Theft Deterrent System: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-155-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 155 FMI 3 - Theft Deterrent System: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-155-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 155 FMI 4 - Theft Deterrent System: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-156-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 1 - Operator Presence: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-156-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 2 - Operator Presence: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-156-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 4 - Operator Presence: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-156-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 156 FMI 5 - Operator Presence: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-157-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 157 FMI 3 - Seat Belt Switch: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |