CID-85-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 85 FMI 2 - Cylinder Cutout #2: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-85-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 85 FMI 3 - Cylinder Cutout #2: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-85-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 85 FMI 4 - Cylinder Cutout #2: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-86-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 86 FMI 1 - Cylinder Cutout #3: Data Valid But Below Normal Operational Range |
heavy-equipment |
Major |
View → |
CID-86-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 86 FMI 3 - Cylinder Cutout #3: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-86-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 86 FMI 4 - Cylinder Cutout #3: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-86-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 86 FMI 5 - Cylinder Cutout #3: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-87-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 2 - Cylinder Cutout #4: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Major |
View → |
CID-87-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 4 - Cylinder Cutout #4: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-87-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 5 - Cylinder Cutout #4: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-87-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 87 FMI 6 - Cylinder Cutout #4: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-88-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 88 FMI 3 - Cylinder Cutout #5: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-88-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 88 FMI 5 - Cylinder Cutout #5: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-88-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 88 FMI 6 - Cylinder Cutout #5: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Major |
View → |
CID-89-FMI-13 |
CAT Electronic Control Module
|
Caterpillar CID 89 FMI 13 - Cylinder Cutout #6: Out of Calibration |
heavy-equipment |
Major |
View → |
CID-9-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 9 FMI 8 - Atmospheric Pressure: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-90-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 0 - Crankcase Breather Filter: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-90-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 1 - Crankcase Breather Filter: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-90-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 2 - Crankcase Breather Filter: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-90-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 90 FMI 4 - Crankcase Breather Filter: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-91-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 3 - Engine Serial Number: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Major |
View → |
CID-91-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 4 - Engine Serial Number: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Major |
View → |
CID-91-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 91 FMI 5 - Engine Serial Number: Current Below Normal, or Open Circuit |
heavy-equipment |
Major |
View → |
CID-92-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 92 FMI 2 - Total Tattletale: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-92-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 92 FMI 3 - Total Tattletale: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-92-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 92 FMI 5 - Total Tattletale: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-93-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 93 FMI 3 - Trip Tattletale: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-93-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 93 FMI 5 - Trip Tattletale: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-93-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 93 FMI 6 - Trip Tattletale: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
CID-93-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 93 FMI 8 - Trip Tattletale: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-94-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 94 FMI 5 - Engine Run Time: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-94-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 94 FMI 8 - Engine Run Time: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-95-FMI-0 |
CAT Electronic Control Module
|
Caterpillar CID 95 FMI 0 - Total Fuel Used: Data Valid But Above Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-95-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 95 FMI 2 - Total Fuel Used: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-95-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 95 FMI 3 - Total Fuel Used: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-96-FMI-1 |
CAT Electronic Control Module
|
Caterpillar CID 96 FMI 1 - Trip Fuel Used: Data Valid But Below Normal Operational Range |
heavy-equipment |
Minor |
View → |
CID-96-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 96 FMI 2 - Trip Fuel Used: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-96-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 96 FMI 3 - Trip Fuel Used: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-96-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 96 FMI 5 - Trip Fuel Used: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-97-FMI-2 |
CAT Electronic Control Module
|
Caterpillar CID 97 FMI 2 - Total Idle Fuel Used: Data Erratic, Intermittent, or Incorrect |
heavy-equipment |
Minor |
View → |
CID-97-FMI-3 |
CAT Electronic Control Module
|
Caterpillar CID 97 FMI 3 - Total Idle Fuel Used: Voltage Above Normal, or Shorted to High Source |
heavy-equipment |
Minor |
View → |
CID-97-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 97 FMI 5 - Total Idle Fuel Used: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-98-FMI-4 |
CAT Electronic Control Module
|
Caterpillar CID 98 FMI 4 - Trip Idle Fuel Used: Voltage Below Normal, or Shorted to Low Source |
heavy-equipment |
Minor |
View → |
CID-98-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 98 FMI 5 - Trip Idle Fuel Used: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-98-FMI-8 |
CAT Electronic Control Module
|
Caterpillar CID 98 FMI 8 - Trip Idle Fuel Used: Abnormal Frequency, Pulse Width, or Period |
heavy-equipment |
Minor |
View → |
CID-99-FMI-5 |
CAT Electronic Control Module
|
Caterpillar CID 99 FMI 5 - Fuel Rate: Current Below Normal, or Open Circuit |
heavy-equipment |
Minor |
View → |
CID-99-FMI-6 |
CAT Electronic Control Module
|
Caterpillar CID 99 FMI 6 - Fuel Rate: Current Above Normal, or Grounded Circuit |
heavy-equipment |
Minor |
View → |
E3002 |
C15 Engine
|
Caterpillar C15 Engine Error Code E3002 |
heavy-equipment |
Major |
View → |
E3003 |
C15 Engine
|
Caterpillar C15 Engine Error Code E3003 |
heavy-equipment |
Major |
View → |
E3004 |
C15 Engine
|
Caterpillar C15 Engine Error Code E3004 |
heavy-equipment |
Critical |
View → |
E3205 |
320 Excavator
|
Caterpillar 320 Excavator Error Code E3205 |
heavy-equipment |
Minor |
View → |
H3102 |
320 Excavator
|
Caterpillar 320 Excavator Error Code H3102 |
heavy-equipment |
Critical |
View → |
SPN 110-FMI 2 |
Caterpillar 988K Wheel Loader
|
Engine Coolant Temperature - Signal Erratic |
heavy-equipment |
Warning |
View → |
SPN 1761-FMI 0 |
Caterpillar 950M Wheel Loader
|
Wheel Speed Sensor - Front Left Error |
heavy-equipment |
Warning |
View → |
SPN 3055-FMI 1 |
Caterpillar C9 Engine
|
DPF Differential Pressure - High |
heavy-equipment |
Warning |
View → |
SPN 3719-FMI 0 |
Caterpillar C9 Engine
|
SCR System - Malfunction/Derate Active |
heavy-equipment |
Critical |
View → |
SPN 5246-FMI 0 |
Caterpillar C9 Engine
|
DEF Inducement/Derate - Active |
heavy-equipment |
Critical |
View → |
SPN 94-FMI 1 |
Caterpillar C9 Engine
|
Fuel Delivery Pressure - Below Normal |
heavy-equipment |
Warning |
View → |