DC overvoltage

ABB Electrical Error vfd

Model: ACS880 | Code: 3210

Applicable Systems
AC500 AC590 ACS580 ACS880

Symptoms

DC link voltage exceeded trip level.

Possible Causes

Deceleration time too short, regenerative energy too high, or supply voltage too high.

Troubleshooting Steps

Extend deceleration time, install brake chopper/resistor, check supply voltage.

How to Reset

Fix cause and reset

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: ABB ACS880 fault manual

Category: Electrical