Applicable Systems
ACS580
ACS880
ACS510
ACS550
ACS800
Symptoms
The motor nominal values in parameter group 99 are incorrectly set or inconsistent. The drive cannot properly identify or control the motor with the current settings.
Possible Causes
- Motor rated voltage, current, or power in parameters 99.04-99.07 do not match the motor nameplate
- Motor rated speed or frequency is incorrect
- Motor type selection (99.03) does not match the actual motor type
Troubleshooting Steps
- Step 1: Check all motor nameplate data against drive parameters in group 99
All parameters match the nameplate exactly - Step 2: Verify the motor type selection (induction, permanent magnet, etc.)
Motor type is correctly selected - Step 3: Run the motor identification routine (ID Run) after correcting parameters
ID Run completes successfully
How to Reset
To reset: Correct the motor parameters and run ID Run. The warning clears automatically when parameters are correct.
Source: ABB ACS580 Firmware Manual; ABB变频器故障代码大全 (11467.com)