Baldor MicroFlex Error Code B013

Baldor PLC & VFD Major Position

Model: MicroFlex | Code: B013

Applicable Systems
MicroFlex

Symptoms

The MicroFlex reports a following error fault. The position following error exceeded the tolerance, indicating the axis cannot track the command.

Possible Causes

  • Load torque exceeding the motor and drive capacity
  • Position loop gain too low for the load inertia
  • Mechanical friction or binding preventing smooth motion

Troubleshooting Steps

  1. Step 1: Check the mechanical system for binding, friction, or excessive load
    Mechanical system moves freely without binding
  2. Step 2: Increase the position loop gain within stability limits
    Following error is within the tolerance band
  3. Step 3: If load exceeds capacity, upgrade the motor and drive sizing
    System tracks the command within tolerance

How to Reset

To reset: Reduce the following error below tolerance, then reset and restart.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Baldor MicroFlex Drive Manual, Baldor Electric Company/ABB

Category: PLC & VFD