Symptoms

The MicroFlex reports a motor parameter mismatch. The motor parameters in the drive do not match the connected motor specifications.

Possible Causes

  • Motor rated current parameter does not match the motor nameplate
  • Motor rated voltage or power parameter incorrectly set
  • Different motor connected after parameters were configured for another

Troubleshooting Steps

  1. Step 1: Compare the motor parameters in the drive with the motor nameplate
    Parameter mismatch identified
  2. Step 2: Update all motor parameters to match the nameplate values
    All parameters match the nameplate
  3. Step 3: Run auto-tune to verify and fine-tune the motor parameters
    Auto-tune confirms correct parameters

How to Reset

To reset: Correct the motor parameters to match the nameplate, then restart.