Symptoms

The IndraDrive reports a motor ground fault. Leakage current to ground was detected in the motor circuit, indicating insulation breakdown.

Possible Causes

  • Motor winding insulation breakdown to the motor frame
  • Motor cable insulation damage exposing conductor to ground
  • Moisture or water ingress in the motor or junction box

Troubleshooting Steps

  1. Step 1: Test the motor winding insulation to ground with a megger
    Insulation resistance is above the minimum threshold
  2. Step 2: Inspect the motor cable for physical damage or water ingress
    Cable insulation is intact and dry
  3. Step 3: Repair or replace any motor or cable with failed insulation
    Ground fault is cleared after repair

How to Reset

To reset: Fix the motor ground fault, then reset the fault and restart.