Bosch Rexroth IndraDrive Error Code C0410

Bosch Rexroth PLC & VFD Major Brake

Model: IndraDrive | Code: C0410

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a braking resistor overheat fault. The braking resistor temperature exceeded the safe limit due to excessive regenerative duty.

Possible Causes

  • Regenerative duty cycle exceeding the resistor power rating
  • Braking resistor value incorrect causing excessive current
  • Frequent deceleration cycles without adequate cooling time

Troubleshooting Steps

  1. Step 1: Reduce the deceleration frequency or increase the decel time
    Regenerative energy per cycle is reduced
  2. Step 2: Verify the braking resistor matches the drive specified rating
    Resistor rating is adequate for the application
  3. Step 3: Upgrade to a larger braking resistor if duty cycle cannot be reduced
    Larger resistor handles the regenerative load

How to Reset

To reset: Allow the resistor to cool, reduce regenerative duty, then reset.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD