Bosch Rexroth IndraDrive Error Code C0110

Bosch Rexroth PLC & VFD Critical Power

Model: IndraDrive | Code: C0110

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a DC bus overvoltage fault. The bus capacitor voltage exceeded the maximum safe level.

Possible Causes

  • Regenerative energy from deceleration exceeding the braking capacity
  • Input supply voltage at or above the upper specification limit
  • Braking transistor or resistor circuit failure

Troubleshooting Steps

  1. Step 1: Increase the deceleration time to reduce regenerative energy
    DC bus voltage stays below the threshold
  2. Step 2: Check the braking resistor and transistor circuit
    Brake circuit is functional
  3. Step 3: Measure the input supply voltage and verify it is within range
    Input voltage is within the rated range

How to Reset

To reset: Reduce the DC bus voltage below the threshold, then reset.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD