Bosch Rexroth IndraDrive Error Code C0740

Bosch Rexroth PLC & VFD Major Motion

Model: IndraDrive | Code: C0740

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a position limit fault. The axis position exceeded the configured travel limit, halting motion for safety.

Possible Causes

  • Positioning command sent beyond the configured travel limits
  • Encoder feedback error causing false position calculation
  • Home position offset incorrect causing position drift

Troubleshooting Steps

  1. Step 1: Check the position command against the configured travel limits
    Command is within the valid travel range
  2. Step 2: Verify the encoder feedback is accurate and without noise
    Position feedback matches the physical position
  3. Step 3: Re-home the axis if the home offset is incorrect
    Home position is set correctly

How to Reset

To reset: Clear the position limit fault and re-home the axis, then restart.

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD