Bosch Rexroth IndraDrive Error Code C0730

Bosch Rexroth PLC & VFD Major Motion

Model: IndraDrive | Code: C0730

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a following error fault. The position following error exceeded the tolerance, indicating the axis cannot track the command.

Possible Causes

  • Load torque exceeding the motor and drive capacity
  • Position loop gain too low for the load inertia
  • Mechanical friction or binding preventing smooth motion

Troubleshooting Steps

  1. Step 1: Check the mechanical system for binding, friction, or excessive load
    Mechanical system moves freely without binding
  2. Step 2: Increase the position loop gain within stability limits
    Following error is within the tolerance band
  3. Step 3: If load exceeds capacity, upgrade the motor and drive sizing
    System tracks the command within tolerance

How to Reset

To reset: Reduce the following error below tolerance, then reset and restart.

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD