Bosch Rexroth IndraDrive Error Code C0710

Bosch Rexroth PLC & VFD Major Motion

Model: IndraDrive | Code: C0710

Applicable Systems
IndraDrive

Symptoms

The IndraDrive reports a limit switch activation. A travel limit switch was triggered, stopping motion to prevent mechanical overrun.

Possible Causes

  • Axis reached the physical travel limit and activated the limit switch
  • Limit switch wiring fault causing false trigger
  • Positioning error causing the axis to travel beyond the expected range

Troubleshooting Steps

  1. Step 1: Check the limit switch activation and verify the axis position
    Limit switch was correctly triggered at the travel end
  2. Step 2: Verify the limit switch wiring and function in the drive system
    Limit switch operates correctly
  3. Step 3: Clear the limit switch and jog the axis back to the valid travel range
    Axis is back within the valid travel zone

How to Reset

To reset: Clear the limit switch and move the axis to valid range, then restart.

Source: Bosch Rexroth IndraDrive Functional Description, Bosch Rexroth AG

Category: PLC & VFD