Caterpillar Cat ET Error Code CID 485 FMI 4

Caterpillar Generator Critical Communication

Model: Cat ET / EMCP 4.x | Code: 485-4

Applicable Systems
EMCP 4.2

Symptoms

CID 485 (CAN Bus Communication): Voltage below normal or shorted low. The Caterpillar Electronic Technician (Cat ET) displays this fault. Machine operation may be derated or shut down depending on severity.

Possible Causes

  • Sensor or actuator for CAN Bus Communication failed or out of range
  • Wiring harness for CID 485 circuit open, shorted, or corroded
  • ECM parameter for CAN Bus Communication out of calibration
  • Mechanical or hydraulic issue affecting the component

Troubleshooting Steps

  1. Step 1: Connect Cat ET and read active fault codes for CID 485
    Fault code 485-4 displayed with timestamp and component data
  2. Step 2: Inspect wiring harness and connector for CID 485 (CAN Bus Communication)
    Wiring intact, connector clean and seated
  3. Step 3: Test CAN Bus Communication sensor or actuator output
    Output within Caterpillar specification range
  4. Step 4: Check ECM for stored parameters and calibrate if needed
    Parameters within factory specification
  5. Step 5: Clear fault with Cat ET and verify no re-occurrence
    Fault cleared and does not return after test cycle

How to Reset

To reset: 1) Correct the underlying fault for CID 485. 2) Press FAULT RESET on the EMCP panel or clear via Cat ET. 3) Verify machine returns to normal operation. Caution: Do not reset without repairing the fault as the machine may operate in derated mode.

Frequently Asked Questions

  • Q: What does CID 485 mean on Caterpillar equipment?

    CID 485 refers to CAN Bus Communication. It is a standard Caterpillar Component Identifier used in diagnostic systems.

  • Q: What does FMI 4 mean?

    FMI 4 indicates: Voltage below normal or shorted low. FMI (Failure Mode Identifier) describes the type of failure detected.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Caterpillar SAE J1939 CID/FMI Reference, wholefleet.ca/motorsymphdiesel.com

Category: Generator