Caterpillar Cat ET Error Code CID 507 FMI 5

Caterpillar Generator Major Pressure

Model: Cat ET / EMCP 4.x | Code: 507-5

Applicable Systems
EMCP 4.2

Symptoms

CID 507 (Pump Discharge Pressure): Current below normal or open circuit. The Caterpillar Electronic Technician (Cat ET) displays this fault. Machine operation may be derated or shut down depending on severity.

Possible Causes

  • Sensor or actuator for Pump Discharge Pressure failed or out of range
  • Wiring harness for CID 507 circuit open, shorted, or corroded
  • ECM parameter for Pump Discharge Pressure out of calibration
  • Mechanical or hydraulic issue affecting the component

Troubleshooting Steps

  1. Step 1: Connect Cat ET and read active fault codes for CID 507
    Fault code 507-5 displayed with timestamp and component data
  2. Step 2: Inspect wiring harness and connector for CID 507 (Pump Discharge Pressure)
    Wiring intact, connector clean and seated
  3. Step 3: Test Pump Discharge Pressure sensor or actuator output
    Output within Caterpillar specification range
  4. Step 4: Check ECM for stored parameters and calibrate if needed
    Parameters within factory specification
  5. Step 5: Clear fault with Cat ET and verify no re-occurrence
    Fault cleared and does not return after test cycle

How to Reset

To reset: 1) Correct the underlying fault for CID 507. 2) Press FAULT RESET on the EMCP panel or clear via Cat ET. 3) Verify machine returns to normal operation. Caution: Do not reset without repairing the fault as the machine may operate in derated mode.

Frequently Asked Questions

  • Q: What does CID 507 mean on Caterpillar equipment?

    CID 507 refers to Pump Discharge Pressure. It is a standard Caterpillar Component Identifier used in diagnostic systems.

  • Q: What does FMI 5 mean?

    FMI 5 indicates: Current below normal or open circuit. FMI (Failure Mode Identifier) describes the type of failure detected.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Caterpillar SAE J1939 CID/FMI Reference, wholefleet.ca/motorsymphdiesel.com

Category: Generator