Caterpillar CID 55 FMI 13 - Injection Actuation Pressure Control Valve (Current) Out of Calibration

Model: Caterpillar Heavy Equipment | Code: 55-13

Applicable Systems
EMCP 4.2

Symptoms

The Caterpillar equipment displays fault code CID 55 FMI 13 on the instrument panel or diagnostic display. The injection actuation pressure control valve (current) has reported: out of calibration. The check engine or warning indicator may illuminate. Equipment performance may be degraded.

Possible Causes

  • Injection Actuation Pressure Control Valve (Current) sensor or component fault - out of calibration
  • Wiring harness damage, corrosion, or loose connection
  • Connector water intrusion or pin corrosion
  • ECM input/output circuit fault
  • Mechanical failure of the monitored component

Troubleshooting Steps

  1. Step 1: Connect Caterpillar ET (Electronic Technician) or EST diagnostic tool and read all active and logged fault codes
    All fault codes are retrieved with CID, FMI, and module information
  2. Step 2: Inspect the wiring harness and connector for the CID component for damage, corrosion, or loose pins
    Wiring and connector are in good condition
  3. Step 3: Use a digital multimeter to check the Injection Actuation Pressure Control Valve (Current) signal voltage, ground, and 5V reference per Caterpillar service manual
    Values match specifications in the service manual
  4. Step 4: Perform component-level testing: check sensor resistance, actuator operation, or mechanical function as applicable
    Component passes or fails definitively
  5. Step 5: Clear codes and operate equipment to verify the fault does not return
    Code does not return and system operates normally

How to Reset

To reset CID 55 FMI 13: 1) Repair the underlying fault. 2) Use Caterpillar ET to clear logged and active codes. 3) Cycle the key switch (off for 10 seconds, then on). 4) Operate equipment to verify. 5) If code returns, continue diagnosis. Caution: Do not clear codes without fixing the root cause.

Frequently Asked Questions

  • Q: What does Caterpillar CID 55 FMI 13 mean?

    CID 55 identifies the Injection Actuation Pressure Control Valve (Current). FMI 13 indicates: Out of Calibration. This is a Caterpillar diagnostic code from the J1939/SAE standard.

  • Q: How serious is CID 55 FMI 13?

    Severity: Minor. Monitor and service at next opportunity.

  • Q: Can I continue operating with CID 55 FMI 13?

    Yes, but schedule diagnosis promptly.

Source: Caterpillar Service Information System (SIS), J1939/SAE Standard - verified via BING International

Category: Heavy Equipment