Applicable Systems
EMCP 4.2
Symptoms
The Caterpillar equipment displays fault code CID 70 FMI 3 on the instrument panel or diagnostic display. The injection actuation pressure sensor (open) has reported: voltage above normal/shorted high. The check engine or warning indicator may illuminate. Equipment performance may be degraded.
Possible Causes
- Injection Actuation Pressure Sensor (Open) sensor or component fault - voltage above normal/shorted high
- Wiring harness damage, corrosion, or loose connection
- Connector water intrusion or pin corrosion
- ECM input/output circuit fault
- Mechanical failure of the monitored component
Troubleshooting Steps
- Step 1: Connect Caterpillar ET (Electronic Technician) or EST diagnostic tool and read all active and logged fault codes
All fault codes are retrieved with CID, FMI, and module information - Step 2: Inspect the wiring harness and connector for the CID component for damage, corrosion, or loose pins
Wiring and connector are in good condition - Step 3: Use a digital multimeter to check the Injection Actuation Pressure Sensor (Open) signal voltage, ground, and 5V reference per Caterpillar service manual
Values match specifications in the service manual - Step 4: Perform component-level testing: check sensor resistance, actuator operation, or mechanical function as applicable
Component passes or fails definitively - Step 5: Clear codes and operate equipment to verify the fault does not return
Code does not return and system operates normally
How to Reset
To reset CID 70 FMI 3: 1) Repair the underlying fault. 2) Use Caterpillar ET to clear logged and active codes. 3) Cycle the key switch (off for 10 seconds, then on). 4) Operate equipment to verify. 5) If code returns, continue diagnosis. Caution: Do not clear codes without fixing the root cause.
Frequently Asked Questions
- Q: What does Caterpillar CID 70 FMI 3 mean?
CID 70 identifies the Injection Actuation Pressure Sensor (Open). FMI 3 indicates: Voltage Above Normal/Shorted High. This is a Caterpillar diagnostic code from the J1939/SAE standard.
- Q: How serious is CID 70 FMI 3?
Severity: Major. Reduce equipment load and schedule service.
- Q: Can I continue operating with CID 70 FMI 3?
Reduce load and proceed cautiously to a service location.