Caterpillar EMCP 4.2 Error Code C015

Caterpillar Generator Critical Power

Model: EMCP 4.2 | Code: C015

Applicable Systems
EMCP 4.2

Symptoms

The generator set reports a loss of excitation. The alternator excitation field has been lost.

Possible Causes

  • Exciter winding failure
  • Automatic voltage regulator failure
  • Excitation circuit breaker or fuse tripped

Troubleshooting Steps

  1. Step 1: Check the excitation system voltage
    Voltage is present at the exciter
  2. Step 2: Verify the AVR operation
    AVR delivers correct excitation current
  3. Step 3: Check the excitation circuit protection
    Protection is reset or fuse is good

How to Reset

To reset: Restore excitation, then reset the protection.

Source: Caterpillar Generator Set Manual, Caterpillar Inc.

Category: Generator