Caterpillar CID 106 FMI 1 - Desired Fan Speed: Data Valid But Below Normal Operational Range

Model: CAT Electronic Control Module | Code: CID-106-FMI-1

Applicable Systems
EMCP 4.2

Symptoms

The Caterpillar Electronic Technician (ET) displays CID 106 with FMI 1: Desired Fan Speed - Data Valid But Below Normal Operational Range Most Severe Level. The specific symptoms depend on the component and severity level. The engine or machine may exhibit reduced performance, warning indicators, or protective shutdown.

Possible Causes

  • Desired Fan Speed sensor or actuator fault - Data Valid But Below Normal Operational Range
  • Wiring harness damage, corrosion, or loose connections
  • Connector pin corrosion or terminal damage
  • ECM internal circuit or processor fault
  • Component mechanical failure related to Desired Fan Speed

Troubleshooting Steps

  1. Step 1: Connect Caterpillar ET and retrieve active diagnostic codes for CID 106 FMI 1
    Diagnostic code details and freeze frame data retrieved
  2. Step 2: Inspect the wiring harness and connectors for the affected component
    No visible damage, chafing, or corrosion found
  3. Step 3: Check sensor/actuator power supply, ground, and signal circuits with a multimeter
    Values match CAT specifications or discrepancies identified
  4. Step 4: Perform component-specific tests per CAT service manual procedures
    Component passes or fails definitive test
  5. Step 5: Clear diagnostic codes and operate machine through normal cycle to verify repair
    Code does not return and system operates normally

How to Reset

To reset Caterpillar CID 106 FMI 1: 1) Repair the underlying fault per troubleshooting steps. 2) Use Caterpillar ET to clear the diagnostic code. 3) Cycle the ignition key off for 30 seconds, then on. 4) Operate the machine through normal conditions. 5) If the code returns, contact an authorized CAT dealer for further diagnosis.

Frequently Asked Questions

  • Q: What does Caterpillar CID 106 FMI 1 mean?

    CID 106 FMI 1 indicates: Desired Fan Speed - Data Valid But Below Normal Operational Range Most Severe Level. This is a Caterpillar diagnostic code related to Cooling.

  • Q: How do I clear Caterpillar CID 106 FMI 1?

    Fix the root cause, then use Caterpillar ET to clear the code. If persistent, contact a CAT dealer.

  • Q: Is Caterpillar CID 106 FMI 1 critical?

    Severity: Minor. Monitor and service at next opportunity.

Source: Caterpillar Electronic Technician (ET) / CID-FMI Reference Guide