DPF Differential Pressure - High

Caterpillar Heavy Equipment Warning Exhaust

Model: Caterpillar C9 Engine | Code: SPN 3055-FMI 1

Applicable Systems
EMCP 4.2

Symptoms

DPF restriction warning; engine derate active; soot loading above regeneration threshold.

Possible Causes

  • DPF soot accumulation exceeding active regen threshold
  • Exhaust backpressure sensor faulty
  • DPF substrate partial blockage

Troubleshooting Steps

  1. Step 1: Check DPF soot loading via Cat ET
    Soot loading < 100% before regen needed
  2. Step 2: Initiate stationary DPF regeneration via Cat ET
    Regen completes, soot load < 30%
  3. Step 3: Inspect DPF differential pressure sensor
    Sensor reading matches mechanical gauge
  4. Step 4: Check exhaust system for leaks before DPF
    No exhaust leaks found
  5. Step 5: Clear code and verify DPF pressure within spec
    DPF diff pressure < 3 kPa at idle

How to Reset

Clear via Cat ET after successful DPF regeneration.

Common Replacement Parts

  • DPF Differential Pressure Sensor P/N: 368-8531

Frequently Asked Questions

  • Q: How often should DPF regeneration occur?

    Active regen typically every 50-100 hours depending on load cycle. Stationary regen when soot load reaches threshold.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: verizonconnect.com DTC guide

Category: Heavy Equipment