Demag DR-PRO 50t Error Code D010

Demag Crane Critical Safety

Model: DR-PRO 50t | Code: D010

Applicable Systems
DR-PRO 50t

Symptoms

The crane reports a safety limit overtravel. The hook or trolley has moved beyond the safety limit position.

Possible Causes

  • Safety limit switch misadjusted or bypassed
  • Operator error driving beyond the limit
  • Limit switch cam or actuator damaged

Troubleshooting Steps

  1. Step 1: Verify the safety limit switch adjustment
    Switch activates at the correct position
  2. Step 2: Inspect the limit switch cam and actuator
    Components are intact
  3. Step 3: Check that the switch is not bypassed
    Safety circuit is intact

How to Reset

To reset: Move the crane within limits, repair the switch, then reset the safety circuit.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Demag DR Rope Hoist Manual, Demag Cranes & Components GmbH

Category: Crane