Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
Reference point return failed due to insufficient movement or speed.
Possible Causes
- The axis did not travel far enough to reach the reference point.
- The reference point return speed was too low.
Troubleshooting Steps
- Step 1: Check that the axis can move at least one turn of the encoder before the dog.
Insufficient travel identified. - Step 2: Increase the reference point return speed or move the axis closer.
Reference point return completes successfully.
How to Reset
Adjust the return parameters and retry to clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation
Category: CNC
No comments yet. Be the first to share your experience!