Gardner Denver Electra Saver Error Code G005

Gardner Denver Compressor Minor Communication

Model: Electra Saver | Code: G005

Applicable Systems
Electra Saver

Symptoms

Electra Saver PLC has lost communication with the optional remote monitoring gateway. Local compressor operation continues normally; remote monitoring and email alerts are unavailable.

Possible Causes

  • Ethernet cable disconnected or damaged between the PLC communication module and the network switch
  • IP address conflict or subnet mismatch after a network change
  • Gateway firmware incompatible with the PLC program version
  • Firewall blocking outbound ports 80, 443, or 502 required for cloud communication

Troubleshooting Steps

  1. Step 1: Check the link and activity LEDs on the PLC Ethernet module and the switch port
    Re-seat the RJ45 connector and swap with a known-good Cat5e cable
  2. Step 2: Access the PLC program and verify the IP address, subnet mask, and gateway settings
    Ensure the IP is unique on the network and in the same subnet as the gateway
  3. Step 3: Check the gateway firmware version and compare to the PLC program revision notes
    Update the gateway firmware via USB or network if a version mismatch is found
  4. Step 4: Test connectivity to the cloud server by pinging the gateway URL from a PC on the same network
    Open firewall ports 80, 443, and 502 outbound if pings succeed but cloud registration fails

How to Reset

Reset: Once the network link is restored, the PLC auto-reconnects to the gateway within 2 minutes. No manual reset is required on the compressor.

Common Replacement Parts

  • GD-1040: Ethernet communication module (For Allen-Bradley MicroLogix, 1761-NET-ENI equivalent)
  • GD-1041: Remote monitoring gateway (Cellular/Ethernet dual-mode, with antenna kit)
  • GD-1042: Industrial Ethernet cable, 5 m (Cat6, shielded, with strain relief)

Frequently Asked Questions

  • Q: Does the compressor stop if remote monitoring fails?

    No. The compressor continues running with local pressure control. Only remote visibility and alerts are affected.

  • Q: What data does the gateway send?

    Run status, pressure, temperature, running hours, alarm history, and energy consumption. Data is sent every 5 minutes via HTTPS.