Haas CNC Error Code 109

Haas CNC Major Power

Model: CNC | Code: 109

Applicable Systems
Haas CNC Mill (VF/VM Series)

Symptoms

DC bus voltage is low, indicating a power supply issue.

Possible Causes

  • Incoming line voltage is below specification.
  • DC bus capacitor degradation or power supply fault.

Troubleshooting Steps

  1. Step 1: Check the incoming line voltage.
    Low voltage identified.
  2. Step 2: Fix the power supply or replace faulty components.
    DC bus voltage restored to normal.

How to Reset

Fix the DC bus voltage and reset to clear the alarm.