Heidelberg Speedmaster XL 106 Error Code 0102

Heidelberg Printing Major Fluid

Model: Speedmaster XL 106 | Code: 0102

Applicable Systems
Speedmaster XL 106

Symptoms

The printing press reports a dampening solution flow anomaly. The fountain solution flow rate is outside the normal operating range.

Possible Causes

  • Fountain solution pump filter clogged
  • Dampening system solenoid valve malfunction
  • Fountain solution level in the tank low

Troubleshooting Steps

  1. Step 1: Check the fountain solution level in the supply tank
    Tank is filled above the minimum level
  2. Step 2: Inspect and clean the pump filter
    Filter is clean and flow is restored
  3. Step 3: Test the dampening solenoid valve operation
    Valve opens and closes correctly

How to Reset

To reset: Restore correct fountain solution flow, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Heidelberg Speedmaster Operating Manual, Heidelberger Druckmaschinen AG

Category: Printing