Heidelberg Speedmaster XL 106 Error Code 0113

Heidelberg Printing Minor Temperature

Model: Speedmaster XL 106 | Code: 0113

Applicable Systems
Speedmaster XL 106

Symptoms

The printing press reports a plate temperature anomaly. The plate cylinder temperature is outside the normal operating range.

Possible Causes

  • Plate cylinder cooling channel blocked
  • Temperature sensor calibration drift
  • Extended high-speed operation generating excess heat

Troubleshooting Steps

  1. Step 1: Check the plate cylinder cooling water circuit
    Cooling water flows at the specified rate
  2. Step 2: Verify the temperature sensor reading against a reference
    Sensor reads accurately
  3. Step 3: Reduce press speed if temperature remains elevated
    Temperature stabilizes within range

How to Reset

To reset: Restore normal plate temperature, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Heidelberg Speedmaster Operating Manual, Heidelberger Druckmaschinen AG