Symptoms

The WJ200 reports a CT detection abnormality. The internal current sensor circuit reported an error.

Possible Causes

  • Internal current sensor (CT) failure or drift
  • CT signal processing circuit fault in the drive
  • Electrical noise interfering with the CT signal lines

Troubleshooting Steps

  1. Step 1: Check the CT signal wiring and connection in the drive
    CT wiring is properly connected
  2. Step 2: Verify the CT output signal with an oscilloscope for proper waveform
    CT signal is clean and accurate
  3. Step 3: If the CT is defective, replace the drive unit
    New unit has a functional current sensor

How to Reset

To reset: Fix the CT circuit or replace the unit, then reset.