Applicable Systems
SUN2000
Symptoms
Fan fault. The inverter cooling fan has failed or is not running at the expected speed. This may lead toovertemperature if the inverter is under load.
Possible Causes
- Fan motor failure: bearing seized or winding open
- Fan connector loose or disconnected
- Fan driver circuit on control board fault
- Fan obstruction by debris or insect nest
Troubleshooting Steps
- Step 1: Check the equipment status and fault indicators to confirm the active fault code
Fault indicator or HMI displays code 313 as active - Step 2: Verify all electrical connections, wiring harnesses, and connector seating
All connections secure, no corrosion, loose pins, or damaged wires - Step 3: Check ambient temperature around the equipment with a thermometer
Temperature is within the specified operating range (typically 10-40 degrees C) - Step 4: Inspect cooling fan operation, airflow paths, and heat sink for dust or blockage
Fan operating normally, airflow unobstructed, heat sink clean - Step 5: Verify equipment load and duty cycle are within rated capacity
Load and duty cycle within manufacturer specifications - Step 6: Allow equipment to cool below the alarm threshold before attempting reset
Temperature readings return to normal operating range - Step 7: Reset the fault after the temperature has normalized: press RESET on the HMI
Fault clears and equipment resumes operation
How to Reset
To reset: 1) Resolve the temperature issue (fix cooling, reduce load). 2) Wait for temperature to drop below alarm threshold. 3) Press RESET on the HMI. Caution: Repeated overtemperature degrades component lifetime.
Frequently Asked Questions
- Q: What does fault code 313 mean on the Huawei SUN2000?
Fault 313 indicates a temperature-related fault. The equipment has detected a temperature exceeding the safe operating limit. Check the cooling system, ambient temperature, and equipment loading.
- Q: Can I continue operating the equipment with fault 313 active?
No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.
Source: Huawei SUN2000 Series Inverter User Manual, Huawei Official Support (support.huawei.com)
Category: PLC & VFD