Applicable Systems
AKD

Symptoms

The AKD reports an encoder calibration error. The encoder zero position or commutation alignment data is invalid or lost.

Possible Causes

  • Encoder battery backup failure causing calibration data loss
  • Encoder was replaced without performing the calibration procedure
  • Commutation alignment shift due to mechanical coupling change

Troubleshooting Steps

  1. Step 1: Check the encoder battery and replace if depleted
    Battery voltage is adequate
  2. Step 2: Perform the encoder calibration procedure as specified in the manual
    Calibration completes and data is stored
  3. Step 3: Verify the mechanical coupling between motor and encoder is secure
    Coupling is tight with no backlash

How to Reset

To reset: Perform the encoder calibration, then cycle power and restart.

Source: Kollmorgen AKD Drive Manual, Kollmorgen Corporation