Komori Lithrone G40 Error Code K105

Komori Printing Major Mechanical

Model: Lithrone G40 | Code: K105

Applicable Systems
Lithrone G40

Symptoms

The printing press reports an impression cylinder pressure anomaly. The pressure between plate and blanket cylinders is outside specification.

Possible Causes

  • Cylinder packing thickness incorrect
  • Bearer ring wear changing the pressure relationship
  • Pressure setting parameter out of range

Troubleshooting Steps

  1. Step 1: Verify the cylinder packing thickness
    Packing matches the substrate specification
  2. Step 2: Inspect bearer rings for wear
    Rings are within wear tolerance
  3. Step 3: Check and correct the pressure setting
    Pressure is within the specified range

How to Reset

To reset: Adjust the impression pressure, then clear the alarm.

Source: Komori Lithrone Operating Manual, Komori Corporation

Category: Printing