KUKA KRC4 Error Code 119

KUKA Robot Major Motor

Model: KRC4 | Code: 119

Applicable Systems
KR CYBERTECH

Symptoms

Motor overtemperature 2. A secondary motor temperature limit has been exceeded on a different sensor ormonitoring point.

Possible Causes

  • Motor bearing overtemperature from lack of lubrication
  • Motor winding hot spot detected by embedded sensor
  • Motor thermal model calculated temperature from current
  • Secondary thermal sensor triggered

Troubleshooting Steps

  1. Step 1: Check the equipment status and fault indicators to confirm the active fault code
    Fault indicator or HMI displays code 119 as active
  2. Step 2: Verify all electrical connections, wiring harnesses, and connector seating
    All connections secure, no corrosion, loose pins, or damaged wires
  3. Step 3: Check motor cable connections at drive output terminals for correct phase sequence and tightness
    Cables securely connected, phase sequence correct, no loose terminals
  4. Step 4: Measure motor winding insulation resistance with a megger (500V DC minimum)
    Insulation resistance above minimum value (typically > 1 Megaohm)
  5. Step 5: Verify drive parameter settings match motor nameplate data (current, voltage, power, RPM)
    All motor nameplate parameters correctly entered in drive
  6. Step 6: Inspect motor for mechanical overload, bearing seizure, or driven equipment jam
    Motor rotates freely, no mechanical binding or excessive load
  7. Step 7: Reset the fault after fixing the root cause: clear the fault via HMI or power-cycle
    Fault clears and drive resumes normal operation without recurrence

How to Reset

To reset: 1) Identify and fix the root cause described in the fault symptoms. 2) Press RESET on the HMI or controller, or power-cycle the equipment. 3) If the fault recurs, contact manufacturer service. Caution: Document the fault code and context before resetting.

Frequently Asked Questions

  • Q: What does fault code 119 mean on the KUKA KRC4?

    Fault 119 on the KUKA KRC4 indicates: Motor overtemperature 2. A secondary motor temperature limit has been exceeded on a different sensor or monitoring point. Refer to the equipment manual and manufacturer support for specific troubleshooting steps.

  • Q: Can I continue operating the equipment with fault 119 active?

    No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.

Source: KUKA Robot Controller KRC4 Operating Manual, KUKA Roboter GmbH Documentation

Category: Robot