Indoor Temperature Sensor Fault

Lennox HVAC Residential Warning HVAC

Model: Lennox S30 Thermostat | Code: Lennox E1

Applicable Systems
S30 Thermostat EL280 Furnace XC21 Condenser Merit Series

Symptoms

Indoor temperature sensor reading out of range; thermostat cannot maintain setpoint; comfort control degraded.

Possible Causes

  • Temperature sensor open/short circuit
  • Sensor wiring damaged
  • Thermostat internal sensor failure

Troubleshooting Steps

  1. Step 1: Check indoor temp sensor resistance at thermostat
    Resistance matches temp chart
  2. Step 2: Inspect sensor wiring for damage
    Wiring intact
  3. Step 3: Verify sensor reading matches room temperature
    Reading within 2C of actual
  4. Step 4: Replace sensor if reading incorrect
    New sensor reading accurate
  5. Step 5: Clear code and verify thermostat operation
    Thermostat maintains setpoint

How to Reset

Clear via thermostat menu: Settings > Diagnostics > Clear Faults.

Common Replacement Parts

  • Lennox S30 Indoor Temperature Sensor

Frequently Asked Questions

  • Q: Where is the temp sensor on Lennox S30?

    Integrated in the S30 thermostat. Some installations use remote sensor (1032-R) for better placement. Check installation configuration.

Source: Lennox S30 Installation Manual

Category: HVAC Residential