Outdoor Temperature Sensor Fault

Lennox HVAC Residential Warning HVAC

Model: Lennox S30 Thermostat | Code: Lennox E2

Applicable Systems
S30 Thermostat EL280 Furnace XC21 Condenser Merit Series

Symptoms

Outdoor temperature sensor reading abnormal; thermostat may not optimize heating/cooling switch-over; efficiency reduced.

Possible Causes

  • Outdoor sensor exposed to direct sun (wrong placement)
  • Sensor wiring damaged by weather/animals
  • Sensor internal failure from moisture

Troubleshooting Steps

  1. Step 1: Check outdoor sensor placement (north side, shaded)
    Sensor properly shaded
  2. Step 2: Inspect sensor wiring for outdoor damage
    Wiring intact, no chew marks
  3. Step 3: Check sensor resistance vs outdoor temp chart
    Resistance matches chart
  4. Step 4: Replace sensor if resistance out of spec
    New sensor reading accurate
  5. Step 5: Clear code and verify outdoor temp reading
    Reading matches local weather data

How to Reset

Clear via thermostat diagnostics menu after sensor service.

Common Replacement Parts

  • Lennox Outdoor Temperature Sensor P/N: 1032-R

Frequently Asked Questions

  • Q: Where to place outdoor temp sensor?

    North side of building, under eave, away from vents/exhausts. Must be shaded and at least 5 feet above ground.

Source: Lennox S30 Installation Manual

Category: HVAC Residential