Lincoln Electric Invertec 170S Error Code Voltage Lockout

Model: Invertec 170S | Code: Voltage Lockout

Applicable Systems
Power Wave ACDC1000SD

Symptoms

The welder displays a Voltage Lockout indication (LED blinks), indicating an internal auxiliary undervoltage condition has been detected.

Possible Causes

  • Input mains voltage dropped below the rated minimum for the welder
  • Input power cable too long or undersized causing voltage drop
  • Internal auxiliary power supply circuit fault
  • Mains power supply unstable with frequent voltage dips

Troubleshooting Steps

  1. Step 1: Check input mains voltage at the welder input terminals
    Voltage must be within the rated range printed on the nameplate
  2. Step 2: Verify input cable size and length meet specifications
    Cable must be sized to prevent excessive voltage drop under load
  3. Step 3: Power cycle the welder by turning off then on the mains switch
    Welder should restart normally if voltage is within range
  4. Step 4: If voltage is consistently low, install a voltage stabilizer
    Stabilizer must handle the welder's maximum input current

How to Reset

To reset: 1) Verify input voltage is within rated range. 2) Turn OFF the Mains Switch. 3) Wait a few seconds. 4) Turn ON the Mains Switch to restart. If the error remains, maintenance is required.

Frequently Asked Questions

  • Q: What input voltage triggers Voltage Lockout?

    Voltage Lockout triggers when the internal auxiliary voltage drops below the threshold, typically when input voltage falls below 85% of rated voltage.

  • Q: Can I continue welding with Voltage Lockout blinking?

    No. The welder disables output when Voltage Lockout is detected. Input voltage must be corrected before resuming operation.