Applicable Systems
MELSEC FX3U
MELSEC FX5U
FR-A800
FR-A700
MR-J4
iQ-R Motion Controller (R32MTCPU/R16MTCPU)
Symptoms
Machine control setting data incorrect. Auxiliary point/central point overflow. The machine does not start. Error code 1FE0H with details code 0066H.
Possible Causes
- The auxiliary point/central point of circular interpolation control is world/base/tool coordinate system, and the specified address is outside the range for 32-bit integer (signed).
Troubleshooting Steps
- Step 1: Correct the point block address specified to the auxiliary point/central point, or the setting of the base transformation value.
Refer to manual for details
How to Reset
Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.
Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3
Category: PLC & VFD