Mitsubishi iQ-R Motion Controller Error Code 0EE0H

Mitsubishi PLC & VFD Warning Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 0EE0H

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

A warning has occurred in the machine control setting data. The machine continues operating but the setting data has an issue.

Possible Causes

  • Parameter setting outside range, invalid specification, or incompatible setting in positioning data or machine parameters.

Troubleshooting Steps

  1. Step 1: Check the details code stored in the machine warning code register (D53171). Correct the corresponding parameter setting.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3

Category: PLC & VFD