Applicable Systems
MELSEC FX3U
MELSEC FX5U
FR-A800
FR-A700
MR-J4
iQ-R Motion Controller (R32MTCPU/R16MTCPU)
Symptoms
Machine control setting data incorrect. Central point/end point setting error (central point circular). The machine does not start. Error code 1FE0H with details code 0065H.
Possible Causes
- The address specification does not make an arc at 3D circular interpolation control with central point specification.
Troubleshooting Steps
- Step 1: Correct the point block address specified to the end point/central point.
Refer to manual for details
How to Reset
Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.
Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3