Applicable Systems
MELSEC FX3U
MELSEC FX5U
FR-A800
FR-A700
MR-J4
iQ-R Motion Controller (R32MTCPU/R16MTCPU)
Symptoms
Machine control setting data incorrect. Speed restriction value over. The machine does not start. Error code 1FE0H with details code 00F3H.
Possible Causes
- The speed of command speed x override ratio is outside the range of 0 to speed limit value. Or override ratio exceeds 1000[x0.1%] under joint interpolation speed restriction.
Troubleshooting Steps
- Step 1: Correct the command speed or override ratio so the speed is within the range. Set the override ratio within 0 to 1000[x0.1%] under joint interpolation speed restriction.
Refer to manual for details
How to Reset
Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.
Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3