Applicable Systems
MELSEC FX3U
MELSEC FX5U
FR-A800
FR-A700
MR-J4
iQ-R Motion Controller (R32MTCPU/R16MTCPU)
Symptoms
Machine control system information event. The override ratio was set to 0 at start or updated to 0 during control.
Possible Causes
- Override ratio set to 0 at start, or updated to 0 during control.
Troubleshooting Steps
- Step 1: Set the override ratio to a non-zero value if machine movement is expected.
Refer to manual for details
How to Reset
Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3
Category: PLC & VFD