Mitsubishi iQ-R Motion Controller Error Code 1FE1H

Mitsubishi PLC & VFD Minor Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE1H

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

A machine library error has occurred. Base/tool transformation change or attitude flag switching cannot be performed.

Possible Causes

  • Machine library settings are incorrect or incomplete. Details code identifies the specific configuration issue.

Troubleshooting Steps

  1. Step 1: Check the details code. Set the correct machine library parameters per the machine library manual.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3