Mitsubishi iQ-R Motion Controller Error Code 1FE1H (Details: 0604H)

Mitsubishi PLC & VFD Moderate Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE1H (Details: 0604H)

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

Machine configuration error or machine library error. Address outside range. The machine does not start. Error code 1FE1H/30FAH with details code 0604H.

Possible Causes

  • The address or movement amount of the point block specified in the positioning point is outside the setting range.

Troubleshooting Steps

  1. Step 1: Set the address or movement amount of the point block that matches the machine type. Refer to the machine library manual.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3