Mitsubishi iQ-R Motion Controller Error Code 1FE5H

Mitsubishi PLC & VFD Minor Error Motion Control

Model: iQ-R Motion Controller (R32MTCPU/R16MTCPU) | Code: 1FE5H

Applicable Systems
MELSEC FX3U MELSEC FX5U FR-A800 FR-A700 MR-J4 iQ-R Motion Controller (R32MTCPU/R16MTCPU)

Symptoms

A XYZ stroke limit error was detected. Operation stops immediately.

Possible Causes

  • The machine movement trajectory exceeded the XYZ stroke limit upper or lower value.

Troubleshooting Steps

  1. Step 1: Correct the positioning point addresses or stroke limit settings. Perform positioning within the operating range.
    Refer to manual for details

How to Reset

Reset using [Rq.2240] Machine error reset command (M43616+32m) or Error reset (SM50). Clear the root cause before resetting.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: MELSEC iQ-R Motion Controller Programming Manual IB-0300309-L, Appendix 2 & 3