NORD SK Error Code N003

NORD PLC & VFD Major Undervoltage

Model: SK | Code: N003

Applicable Systems
SK

Symptoms

The SK reports a DC bus undervoltage fault. The bus capacitor voltage dropped below the minimum operating level.

Possible Causes

  • Input power supply voltage dip or momentary outage
  • Power supply capacity insufficient for the drive load
  • Rectifier bridge fault reducing DC bus charging

Troubleshooting Steps

  1. Step 1: Measure the input supply voltage during operation
    Voltage remains stable within the rated range
  2. Step 2: Check the rectifier bridge for diode failure
    Rectifier bridge is healthy
  3. Step 3: Install a voltage stabilizer if supply dips are frequent
    Supply voltage is stable

How to Reset

To reset: Restore the DC bus voltage to the rated level, then reset.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: NORD SK Drive System Manual, NORD Drives

Category: PLC & VFD