Otis Gen2/SkyRise Error Code 0004

Otis Elevator Critical Safety

Model: Gen2/SkyRise | Code: 0004

Applicable Systems
SKY-2

Symptoms

The elevator reports a safety gear activation. The progressive safety gear has been triggered, stopping the car.

Possible Causes

  • Overspeed detected by the speed governor
  • Governor rope stretched or tension incorrect
  • Safety gear wedges seized or corroded

Troubleshooting Steps

  1. Step 1: Inspect the speed governor for proper operation
    Governor trips at the correct speed
  2. Step 2: Verify governor rope tension and condition
    Rope is taut and in good condition
  3. Step 3: Check safety gear wedges for free movement
    Wedges move freely without corrosion

How to Reset

To reset: Reset the safety gear, verify the governor, then reset the controller.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Otis Elevator Service Manual, Otis Worldwide Corporation

Category: Elevator