Otis Gen2/SkyRise Error Code 0009

Otis Elevator Major Motor

Model: Gen2/SkyRise | Code: 0009

Applicable Systems
SKY-2

Symptoms

The elevator reports a traction machine overload. The hoist motor current has exceeded the rated value.

Possible Causes

  • Motor overload from excessive load or friction
  • Motor bearing failure causing drag
  • Supply voltage low causing high current

Troubleshooting Steps

  1. Step 1: Check motor current against nameplate FLA
    Current is within rated value
  2. Step 2: Inspect motor bearings for noise and heat
    Bearings are in good condition
  3. Step 3: Verify supply voltage at the motor terminals
    Voltage is within 10 percent of rated

How to Reset

To reset: Clear the overload, allow the motor to cool, then reset.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Otis Elevator Service Manual, Otis Worldwide Corporation