Otis Gen2/SkyRise Error Code 0009

Otis Elevator Major Motor

Model: Gen2/SkyRise | Code: 0009

Applicable Systems
SKY-2

Symptoms

The elevator reports a traction machine overload. The hoist motor current has exceeded the rated value.

Possible Causes

  • Motor overload from excessive load or friction
  • Motor bearing failure causing drag
  • Supply voltage low causing high current

Troubleshooting Steps

  1. Step 1: Check motor current against nameplate FLA
    Current is within rated value
  2. Step 2: Inspect motor bearings for noise and heat
    Bearings are in good condition
  3. Step 3: Verify supply voltage at the motor terminals
    Voltage is within 10 percent of rated

How to Reset

To reset: Clear the overload, allow the motor to cool, then reset.

Source: Otis Elevator Service Manual, Otis Worldwide Corporation

Category: Elevator