Rexroth IndraDrive HCS Error Code F8067

Rexroth PLC & VFD Major Hardware

Model: IndraDrive HCS | Code: F8067

Applicable Systems
EFC FEX FEI HNC

Symptoms

PWM timer synchronization fault. The drive has detected a synchronization error in the PWM (Pulse Width Modulation) timer that controls IGBT switching.

Possible Causes

  • Control board FPGA timing error
  • PWM carrier frequency set too high for the hardware
  • Interference from another drive on the same power supply
  • Firmware version incompatibility with PWM timer hardware

Troubleshooting Steps

  1. Step 1: Check PWM carrier frequency setting in IndraWorks AS
    Frequency within the rated range for the drive model (typically 2-16 kHz)
  2. Step 2: Verify no other drives on the same power supply are causing synchronization issues
    Each drive operates independently without interference
  3. Step 3: Power-cycle the drive to reset the PWM timer
    Timer synchronizes correctly after restart
  4. Step 4: If fault recurs, reload firmware or replace control module
    New control module provides stable PWM timing

How to Reset

1) Check PWM frequency parameter. 2) Power-cycle. 3) Reload firmware. 4) Replace control module if persistent.

Frequently Asked Questions

  • Q: What PWM carrier frequency should I use?

    Default is typically 4-8 kHz. Higher frequencies reduce motor noise but increase drive heating. Consult the motor and drive specifications.

  • Q: Does PWM timer fault affect motor performance?

    Yes. PWM timing errors can cause uneven motor torque, increased ripple, and potential motor heating. Address immediately.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Rexroth IndraDrive HCS/HMS Fault Code List, Bosch Rexroth AG

Category: PLC & VFD