Compressor Overload - High Discharge Temperature

Rheem HVAC Residential Critical HVAC

Model: Rheem RA17 Condenser | Code: Rheem E0

Applicable Systems
RA17 Condenser R96V Furnace RA14 Condenser

Symptoms

Compressor thermal overload tripped due to high discharge temperature; outdoor unit locked out; no cooling.

Possible Causes

  • Dirty condenser coil restricting airflow
  • Refrigerant charge low (superheat too high)
  • Outdoor fan motor not running at full speed
  • Non-condensables in system

Troubleshooting Steps

  1. Step 1: Check condenser coil cleanliness
    Coil clean, airflow adequate
  2. Step 2: Check refrigerant pressures (subcooling/superheat)
    Pressures within spec
  3. Step 3: Verify outdoor fan motor operation
    Fan runs at full speed
  4. Step 4: Check compressor amperage vs nameplate
    Amps within FLA rating
  5. Step 5: Clean coil, adjust charge, replace fan if needed
    Compressor runs without overload

How to Reset

Clear by cycling outdoor unit power; may need manual reset on compressor.

Common Replacement Parts

  • Rheem Outdoor Fan Motor
  • Rheem Capacitor

Frequently Asked Questions

  • Q: What is compressor FLA?

    Full Load Amperage - rated current draw at maximum load. Compressor amps should be at or below FLA during normal operation. Above FLA indicates overload.

Source: Rheem RA17 Service Manual

Category: HVAC Residential