Compressor Overload - High Discharge Temperature

Rheem HVAC Residential Critical HVAC

Model: Rheem RA17 Condenser | Code: Rheem E0

Applicable Systems
RA17 Condenser R96V Furnace RA14 Condenser

Symptoms

Compressor thermal overload tripped due to high discharge temperature; outdoor unit locked out; no cooling.

Possible Causes

  • Dirty condenser coil restricting airflow
  • Refrigerant charge low (superheat too high)
  • Outdoor fan motor not running at full speed
  • Non-condensables in system

Troubleshooting Steps

  1. Step 1: Check condenser coil cleanliness
    Coil clean, airflow adequate
  2. Step 2: Check refrigerant pressures (subcooling/superheat)
    Pressures within spec
  3. Step 3: Verify outdoor fan motor operation
    Fan runs at full speed
  4. Step 4: Check compressor amperage vs nameplate
    Amps within FLA rating
  5. Step 5: Clean coil, adjust charge, replace fan if needed
    Compressor runs without overload

How to Reset

Clear by cycling outdoor unit power; may need manual reset on compressor.

Common Replacement Parts

  • Rheem Outdoor Fan Motor
  • Rheem Capacitor

Frequently Asked Questions

  • Q: What is compressor FLA?

    Full Load Amperage - rated current draw at maximum load. Compressor amps should be at or below FLA during normal operation. Above FLA indicates overload.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Rheem RA17 Service Manual

Category: HVAC Residential