Applicable Systems
Sunny Boy
Symptoms
Grid undervoltage. The inverter measures grid voltage below the minimum allowed value. The inverterdisconnects from the grid.
Possible Causes
- Grid voltage from utility below inverter minimum rating
- Voltage drop in AC wiring from undersized cable or long run
- Grid transformer tap setting too low
- Inverter AC voltage measurement circuit fault
Troubleshooting Steps
- Step 1: Check the equipment status and fault indicators to confirm the active fault code
Fault indicator or HMI displays code 102 as active - Step 2: Verify all electrical connections, wiring harnesses, and connector seating
All connections secure, no corrosion, loose pins, or damaged wires - Step 3: Measure the input power supply voltage at the equipment terminals with a multimeter
Voltage reading is within the equipment's specified operating range - Step 4: Inspect the power input wiring, breakers, and fuses for damage or degradation
Wiring intact, breakers closed, fuses continuous - Step 5: Check for transient voltage events or power quality issues using a power analyzer
No sustained overvoltage, undervoltage, or phase imbalance detected - Step 6: Reset the fault after correcting the power issue: fix root cause, then press RESET or power-cycle
Fault clears and equipment resumes normal operation
How to Reset
To reset: 1) Identify and fix the root cause described in the fault symptoms. 2) Press RESET on the HMI or controller, or power-cycle the equipment. 3) If the fault recurs, contact manufacturer service. Caution: Document the fault code and context before resetting.
Frequently Asked Questions
- Q: What does fault code 102 mean on the SMA Sunny Boy?
Fault 102 on the SMA Sunny Boy indicates: Grid undervoltage. The inverter measures grid voltage below the minimum allowed value. The inverter disconnects from the grid. Refer to the equipment manual and manufacturer support for specific troubleshooting steps.
- Q: Can I continue operating the equipment with fault 102 active?
No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.
Source: SMA Sunny Boy Inverter Installation and Operation Manual, SMA Official Documentation