Applicable Systems
ThyssenKrupp Control System
Symptoms
Selector fault detected during correction run - code 30 00
Possible Causes
- Correction run failed
- selector position error
- floor sensor malfunction
Troubleshooting Steps
- Step 1: Re-run correction run
Verify the fault is resolved after completing this step. - Step 2: check selector sensors
Verify the fault is resolved after completing this step. - Step 3: verify floor data
Verify the fault is resolved after completing this step.
How to Reset
Power cycle; re-run correction
Source: beijiaxin.cn; zhihu.com/p/577262471; renrendoc MC2-C manual
Category: Elevator