Selector fault during correction run

ThyssenKrupp Elevator High Elevator

Model: TCM/MC2 | Code: 30 00

Applicable Systems
ThyssenKrupp Control System

Symptoms

Selector fault detected during correction run - code 30 00

Possible Causes

  • Correction run failed
  • selector position error
  • floor sensor malfunction

Troubleshooting Steps

  1. Step 1: Re-run correction run
    Verify the fault is resolved after completing this step.
  2. Step 2: check selector sensors
    Verify the fault is resolved after completing this step.
  3. Step 3: verify floor data
    Verify the fault is resolved after completing this step.

How to Reset

Power cycle; re-run correction

Source: beijiaxin.cn; zhihu.com/p/577262471; renrendoc MC2-C manual

Category: Elevator