Speed monitoring: speed deviation too large

ThyssenKrupp Elevator High Elevator

Model: TCM/MC2 | Code: 0D 44

Applicable Systems
ThyssenKrupp Control System

Symptoms

Speed deviation from reference too large - code 0D 44

Possible Causes

  • Encoder feedback error
  • speed loop tuning issue
  • load change during running

Troubleshooting Steps

  1. Step 1: Check encoder signal quality
    Verify the fault is resolved after completing this step.
  2. Step 2: re-tune speed loop
    Verify the fault is resolved after completing this step.
  3. Step 3: verify load compensation
    Verify the fault is resolved after completing this step.

How to Reset

Power cycle after tuning

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: beijiaxin.cn; zhihu.com/p/577262471; renrendoc MC2-C manual