Toshiba VF-AS1 Error Code E20

Toshiba PLC & VFD Major Overload

Model: VF-AS1 | Code: E20

Applicable Systems
VF-AS1

Symptoms

The VF-AS1 reports a motor overload fault. The motor thermal model calculated excessive heating based on current and time, tripping to protect the motor.

Possible Causes

  • Motor load torque exceeds the motor rated capacity
  • Duty cycle exceeding the motor thermal class rating
  • Motor cooling insufficient due to blocked ventilation or fan failure

Troubleshooting Steps

  1. Step 1: Check the motor load and verify it is within the rated capacity
    Load torque is within the motor rating
  2. Step 2: Inspect the motor cooling fan and ventilation for blockage
    Motor cooling is adequate and unobstructed
  3. Step 3: Set the motor rated current parameter to match the nameplate value
    Motor thermal model matches the actual motor

How to Reset

To reset: Allow the motor to cool and resolve the overload, then reset.

Source: Toshiba VF-AS1 Inverter Manual, Toshiba Mitsubishi-Electric Industrial Systems